9710 (StorageTek) Addendum for NonStop Servers
9710 ACS Automated Cartridge Subsystem Addendum for the Tandem Environment 
Configuring the 6760 ServerNet/DA and Attached Devices 
8-10
8.7 Troubleshooting Configuration Problems 
If a 6760 adapter is not properly configured after it has been 
installed it in a slot, use the SCF INFO ADAPTER command to 
determine whether the slot is already configured for a different 
adapter.  
If the configuration of an adapter and its devices appears to be 
correct, but the attached devices are not functioning properly, there 
might be a hardware problem.  
8.7.1 Troubleshooting After Installing a 6760 Adapter 
If hardware problems are suspected after the 6760 adapter has been 
installed, do the following: 
1. Use the Tandem Service Management (TSM) package to 
check the hardware. See the next topic, Using TSM to 
Check the Adapter Hardware. 
2. Use the SCF STATUS ADAPTER, DETAIL command to 
check the status of all paths to the adapter and its attached 
devices. 
3. Use the SCF INFO ADAPTER, DETAIL command to 
verify proper configuration. 