8.7.2 Using TSM to Check the Adapter Hardware 
Note: This procedure is limited to checking the adapter hardware.  
Check the status of the adapter hardware using the TSM package: 
1. Log on to the TSM Service Application, and use the tree 
pane to select the group enclosure where the adapter 
resides. 
2. Use the view pane to verify that the adapter is displayed in 
the enclosure.  
The adapter should automatically appear in the view pane 
when it is installed into an appropriate slot. 
3. If the adapter is displayed in the view pane, go to Using 
TSM to Test a 6760 Adapter, SACs, and Attached Devices. 
If the adapter is not displayed, go to step 4. 
4. If the adapter doesn’t appear in the view pane, do the 
following: 
a. Remove the adapter from the slot and inspect the 
adapter connector and the pins on the backplane for 
damage. 
b. Reinstall the adapter.  
c. Verify that each LED is in its normal state. 
On the 6760 adapter, the green power-on LED 
should be lit, and the amber fault LED should light 
briefly and then become unlit shortly after the 
adapter is installed in the slot. 