9710 (StorageTek) Addendum for NonStop Servers
9710 ACS Automated Cartridge Subsystem Addendum for the Tandem Environment
Configuring the 6760 ServerNet/DA and Attached Devices
8-11
8.7.2 Using TSM to Check the Adapter Hardware
Note: This procedure is limited to checking the adapter hardware.
Check the status of the adapter hardware using the TSM package:
1. Log on to the TSM Service Application, and use the tree
pane to select the group enclosure where the adapter
resides.
2. Use the view pane to verify that the adapter is displayed in
the enclosure.
The adapter should automatically appear in the view pane
when it is installed into an appropriate slot.
3. If the adapter is displayed in the view pane, go to Using
TSM to Test a 6760 Adapter, SACs, and Attached Devices.
If the adapter is not displayed, go to step 4.
4. If the adapter doesn’t appear in the view pane, do the
following:
a. Remove the adapter from the slot and inspect the
adapter connector and the pins on the backplane for
damage.
b. Reinstall the adapter.
c. Verify that each LED is in its normal state.
On the 6760 adapter, the green power-on LED
should be lit, and the amber fault LED should light
briefly and then become unlit shortly after the
adapter is installed in the slot.