9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek⢠9710 for the Tandem Environment
The 5155/5159 Digital Linear Tape CRE and NonStop Kernel
9-25
Comparing COUP and PUP Commands With START SCSI
In the G-series releases, the SCF START SCSI command replaces the
COUP START DEVICE command and the PUP UP command.
If necessary, the storage subsystem manager starts the Open SCSI I/O
process if it is not running. When the process is ready, the storage
subsystem manager puts the Open SCSI I/O process into a STARTED
state (the equivalent of a PUP UP command).
The following table compares COUP and PUP commands with the SCF
START SCSI command.
Table 9-9 COUP/PUP Commands Replaced by SCF START SCSI
Command
COUP/PUP Command SCF Command
COUP START DEVICE START SCSI
PUP UP START SCSI
For a complete list of all PUP commands and equivalent SCF commands
for the storage subsystem, see PUP Commands and Equivalent SCG
Commands in SCF Reference Manual for the Storage Subsystem.
START TAPE Command
This subsection describes the details about the START TAPE command.
Use the START TAPE command to assign a tape drive to a specific
Tandem system. The command syntax is:
START TAPE $ tape-name
Wild-card characters are supported.