9710 (StorageTek) Addendum for NonStop Servers

Addendum to the StorageTek 9710 for the Tandem Environment
4
D) ServerNet DA (F-SAC) for the S-Series, Fiber Cable
connected to BEB? BEB securely fastened to the 9710
ACS Tape Cartridge Silo Subsystems Patch Panel?
5. Are the 9710ACS Tape Cartridge Silo Subsystem’s drive(s) terminated
properly with a SCSI terminator(s)?
A) MFC (K-Series) Attachment - terminator must be installed
on the 50 Pin “Centronics” Connector.
B) 3216(K-Series) Attachments - terminator must be installed
on the 68 Pin “Fast SCSI” Connector.
C) PMF and ServerNet/DA (EPIC) for the S-Series
Attachment terminator must be installed on the 50 Pin
“Centronics” Connector.
D) ServerNet/DA (F-SAC) Attachment terminator must be
installed on the 68 Pin “Fast SCSI” Connector.
E) If two drives are daisy chained, is the short SCSI daisy chain
cable installed between the drives?
C) S-Series-Last SCSI device should be terminated.
6. Is the SCSI cable connected to the Compaq System correctly?
A) Copper cable connected to MFC (T16/5165) BIC
connector labeled J5?
B) Fiber cable connected to 3216 BIC?
C) S-Series- The Copper SCSI cable should be connected to
the PMF SCSI connector or the ServerNet DA S-SAC.
D) S-Series The Fiber Cable should be connected to the
ServerNet DA F-SAC.