9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment
10
System Test
1. Turn on power to 9710 ACS Tape Cartridge Silo Subsystem tape drive.
2. Wait for initialization completion.
3. Insert a known good tape cartridge by loading it through the CAP
(Cartridge Access Port).
Load Function
Stage What Happens
1 The robot and the hand move to the selected slot, as
indicated by the request.
2 The cartridge is then removed from the slot and by the
robot hand placed in the drive.
3 The robot hand moves to the drive position and inserts the
cartridge into the drive.
4 The lights remain off until the tape loads to the BOT.
5
After the cartridge is loaded into the drive.
4. Complete tests via Compaq TMDS Quick Tape Test software. The
9710ACS Tape Cartridge Silo Subsystem’s drives respond to TMDS as
a T16/5190 tape drive.
5. If the 9710 ACS Tape Cartridge Silo Subsystem fails TMDS Quick
Tape Test inspect the tape controller (MFC, 3216) that the unit(s) is
attached to. The tables following have symptoms and corrective
actions.