9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment
12
Red LED Lit on a Logic Board
Symptom Corrective Action
1. Red LED on a logic board is
lit for less than 1 minute
after the system starts.
• None; normal self-test operation.
2. Red LED on logic board
stays lit for more than 1
minute.
• If two drives are attached to the
same 3216 controller, make sure
that their SCSI Ids are set to 4 and
5. (“Checking and Setting the SCSI
ID”.)
Green LED Not Lit on a BIC
Symptom Corrective Action
1. Green LED not lit on any
BICs.
• Start the system.
Red LED Lit on a BIC
Symptom Corrective Action
1. Red LED on a BIC is lit for
less than 1 minute after the
system starts.
• None; normal self-test operation.
2. Red LED on a BIC stays lit
for more than 1 minute.
• Replace the BIC FRU.
Green LED on a BEB Not Lit
Symptom Corrective Action
1. Green LED not lit inside
BEB enclosure.
• Make sure the
drive FRU is powered
on.