9710 (StorageTek) Addendum for NonStop Servers

Addendum to the StorageTek 9710 for the Tandem Environment
13
Yellow LED on a BEB Not Lit
Symptom Corrective Action
1. Yellow LED not lit inside
BEB enclosure.
Make sure that both the drive FRU
and 3216 logic board are powered
on.
Check the integrity of the fiber-
optic cable connection:
1. Inspect the cable connectors at
the BIC and BEB ends. Make
sure the connectors have not
been forced in backwards. The
connector keyway must mate
with the key in the receptacle.
2. Replace or inspect the cable for
defects or kinks.
3. Make sure the cable maximum
bend radius of 10 centimeters (4
inches) has not been exceeded.
4. If the yellow LED still does not
light, replace the BIC FRU.
If the 9710ACS Tape Cartridge Silo Subsystem fails TMDS Quick Tape
Test. Replace the tape drive FRU. Call StorageTek: see “StorageTek