9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment 
Installing and Configuring the 9710 Automated Cartridge Subsystem
3-9
3.11  Drive Placement and the SCSI ID 
 A single 9710 Automated Cartridge Subsystem can hold up to ten 
 DLT drive FRUs. Each drive FRU must have a unique SCSI ID to 
 identify the drive to the controller. The drive(s) arrive from the  
factory with a SCSI ID of 5, but it is a good idea to check the SCSI 
ID of each drive FRU whenever installing, replacing, or upgrading 
drives. 
 The MFC supports one drive FRU per controller. This drive FRU 
 must have a SCSI ID of 5. One 3216 tape controller supports up to 
 two drive FRUs. If two drive FRUs are attached to the same 3216 
controller and linked by a daisy-chain cable, the SCSI Ids must be 4 
and 5. See Table 3-2. 
 Table 3-2 Controllers and SCSI IDs 
Controller  Drive FRUs
Supported 
SCSI ID
 MFC 
 1   5 
 3216 
 1   5 
 3216 
 2   4 and 5 
 Drive FRUs are installed in the 9710 Automated Cartridge 
 Subsystem and assigned SCSI Ids according to the following rule: 
 •  When two 5155/5159 drive FRUs are attached to a 3216 tape 
  controller, the 5155/5159 drive FRU on the bottom is SCSI ID  
  4 and the 5155/5159 drive FRU on the top is SCSI ID 5. 
Figure 3-4 shows the drive placement and SCSI IDs for the 
5155/5159 drive FRUs arriving from the factory configured to one 
3216 controller. 