Installing and Configuring the 9710 Automated Cartridge Subsystem  
3-26
3.20  Connecting Fiber-Optic Cable to the 9710 Automated 
Cartridge Subsystem BEB (3216 Only) 
After routing the AC power cords, the fiber-optic cable can be 
connected to the Patch Panel BEB. (The fiber-optic cable is 
installed by Compaq Site Services or a certified cable installer.) 
At the Patch Panel end of the cable assembly, install the fiber-optic 
connector as follows: 
 CAUTION 
Fiber-optic cables have a central core of fragile glass fibers. To 
prevent breakage, avoid bending the cables sharply and do not 
handle them roughly. 
1. Remove the filler plug from the fiber-optic connector receptacle 
on the top of the BEB enclosure. The filler plug is for 
protection during shipping. 
2. Remove the dust cover from the fiber-optic connector on the 
cable. 
3. Hold the connector so that the key way meets the key in the 
BEB enclosure receptacle. See Figure 3-16.  
4. Insert the connector into the receptacle until both cantilever 
arms click into the transceiver device mounted on the enclosure. 
5. Route the fiber-optic cable into the upper and lower cable 
clamps on the module sidewall and fastens the clamps. Route 
the cable into the “Cable Access” channel at the midpoint of the 
Patch Panel.  