9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment 
Installing and Configuring the 9710 Automated Cartridge Subsystem
3-29
If COUP is being used to add the subsystem to the system 
configuration, the operating system image does not need to be 
loaded. If COUP is not used, load the new operating system image 
from the SYSnn subvolume created when the Install program was 
run. Peripheral Utility Program (PUP) or Tandem Maintenance and 
Diagnostic System (TMDS) commands cannot be used if the system 
configuration has not yet been prepared using the Install program. 
For instructions on loading the operating system, see the operations 
manual for the system.  
Note: The 5155/5159 tape drive should be configured as a 5190, 
refer to Chapter 9 for details.  
3.22 Placing the Tape Drives Online after Installation 
After the 5155/5159 drive FRU(s) has been installed and the cables 
have been attached, place the 9710 Automated Cartridge 
Subsystem online. Use the following procedure for each drive FRU 
in the 5155/5159 DLT drive FRU(s): 
1. Verify that the AC power cord for the drive FRU is plugged in 
to a circuit source. 
2. Apply power to the drive FRU by setting the AC power switch 
to the ON (I) position. See Figure 7-18. 
4. Observe the power-up self-test on the Operator’s panel.  
5. If the drive FRU is attached to a 3216 tape controller, verify 
that power is applied to the BEB. (The green LED is lit when 
power is on.) 
6. Check the SCSI ID. (See “Checking and Setting the SCSI 
ID”.) 