9710 (StorageTek) Addendum for NonStop Servers

Addendum to the StorageTek 9710 for the Tandem Environment
Installing and Configuring the 9710 Automated Cartridge Subsystem
3-32
Green LED Not Lit on a Logic Board
Symptom
Corrective Action
1. Green LED not lit
on any logic
boards.
Start the system.
Call the GCSC.
2. Green LED not lit
on one logic
board.
Reseat the logic board:
1. Unscrew the thumbscrews on the
ejectors and then lift both ejectors at
same time to disconnect the logic
board from the backplane.
2. Pull the logic board 2 inches out of
its slot.
3. Push the logic board into its slot
until the front of the logic board is
flush with the other logic boards.
4. Press both ejectors into place at the
same time and then tighten the
thumbscrews.
If the green LED still does not light, call the
GCSC.