9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment
Installing and Configuring the 9710 Automated Cartridge Subsystem
3-36
Yellow LED on a BEB Not Lit
Symptom
Corrective Action
1. Yellow LED not lit inside
BEB enclosure.
• Make sure that both
the drive FRU and
3216 logic board is
powered on.
• Check the integrity of
the fiber-optic cable
connection:
1. Inspect the cable
connectors at the BIC and
BEB ends. Make sure the
connectors have not been
forced in backwards. The
connector keyway must
mate with the key in the
receptacle.
2. Replace or inspect the
cable for defects or kinks.
3. Make sure the cable
maximum bend radius of
10 centimeters (4 inches)
has not been exceeded.
4. If the yellow LED still does
not light, call the GCSC.