9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment 
Configuring the Compaq System for the 9710 Automated Cartridge Subsystem  
6-16
• The SHOW command helps to verify that all required attributes 
have been set. It identifies missing but required attributes with 
an asterisk (*). 
• The ADD command names the device and adds it to the 
configuration file. 
6.4.3.1 Considerations 
• Always use 5190 as the product number when configuring the 
T16/5155/5159 DLTtape Drive FRU. 
• Unit numbers are determined by the controller and must match 
the SCSI ID of the drive. 
• Because an MFC can control only one tape drive, the only valid 
unit number for a drive attached to an MFC is 5. 
• The 3216 controller can control one or two tape drives. If the 
controller manages only one drive, use the default unit number 
(5). If the controller manages two drives, use unit numbers 4 
and 5. 
• Compression as a device attribute can be specified through 
COUP for the T16/5155/5159 DLTtape Drive FRU (Note: 
use “5190” when specifying peripheral in CONFTEXT File).  
Use COUP to enable or disable compression with 
 these attributes: 
Attribute 
5155/5159 DLTtape Subsystem 
Action 
NOCOMPRESSION  Data is written without compression 
COMPRESSION  Data is written using compression 