AM3270 and TR3271 Configuration and Management Manual
SCF Interface to AM3270 and TR3271
AM3270 and TR3271 Configuration and Management Manual—529993-001
4-81
Display for the STATUS SU Command
The display for an SU object with the DETAIL option has the following format:
Name
is the name of the TR3271 subdevice.
State
is the current summary state of the subdevice.
IBM Status/Sense
is the IBM status/sense word.
LastError
is the last error that occurred on the subdevice.
Flags
is a bit array that indicates status information for the subdevice. The status can be
a combination of these bits. The bits, when set on, are:
TR3271 DETAILED STATUS SU
Name............. $TR3271.#TERM2 State............. STARTED
IBM Status/Sense. %0000000 LastError......... 0
Flags............ %0000002 SDN............... 2
Bit Meaning
0 READ request is pending.
1 WRITE request is pending.
2 WRITEREAD request is pending.
3 Not used.
4 Subdevice is waiting for a buffer.
5 Subdevice is busy.
6 Internal use only.
7 Two-step READ is pending.
8 Subdevice is waiting for a real READ.
9 Internal use only.
10 Subsystem is attempting to connect the subdevice. This bit applies
to PTP subdevices only.
11 Subsystem is attempting to disconnect the subdevice. This bit
applies to PTP subdevices only.
12 Not used.