Display for the STATUS SU Command
SDN
is the number of the subdevice.
The STATUS SU, DETAIL display can appear in three different forms. The first form is
used when the protocol for the subdevice is not PTP:
The second form appears when it is possible to establish a connection but no
connection is active:
The third form appears when a connection is active:
System
is the system number of the system on which the connected AM3270 subdevice
resides. This field applies only to PTP subdevices.
LDev
is the logical device number of the connected AM3270 subdevice. This field
applies only to PTP subdevices.
SDN
is the subdevice number of the connected AM3270 subdevice. This field applies
only to PTP subdevices.
CU
is the control unit of the connected AM3270 subdevice. This field applies only to
PTP subdevices.
DA
is the device address of the connected AM3270 subdevice.
13 Not used.
14 Internal use only.
15 Internal use only.
No AM3270 connection is possible - Protocol is not PTP
AM3270 Connection: - None
AM3270 Connection:
System............ 136 LDev.............. 21
SDN............... 1 CU................ 25
DA................ 6