AM3270 and TR3271 Configuration and Management Manual
Attribute Descriptions for AM3270 and TR3271
AM3270 and TR3271 Configuration and Management Manual—529993-001
6-8
POLLTYPE
POLLTYPE
The POLLTYPE attribute specifies the polling type. General means a poll of the
controller itself is performed. Specific means a poll of subdevices associated with
the controller is performed.
PROGRAM
The PROGRAM attribute specifies the name of the CLIP download program file. If
the PROGRAM attribute has been modified, the next START command causes
CLIP software to be downloaded.
PROTOCOL
The PROTOCOL attribute specifies the protocol that will be used by the device
being added or altered. This attribute must be specified.
CRT provides the basic mode of operation for 327x terminals and printers. The
CRT protocol manages requests from an application process on the NonStop
S-series server or Integrity NonStop NS-series server that uses standard 3270
buffer orders and text to communicate with the IBM host as an emulated 327x
terminal subdevice.
ITI provides an interactive interface between the HP host and 327x terminals.
PRT provides line-at-a-time output to 327x printers.
Note: This is an AM3270 attribute.
Default: General
Range: General or Specific
Objects: Lines
Profile Equivalent: GP or SP
Default: $SYSTEM.CSSnn.C0039P00 for AM3270
$SYSTEM.CSSnn.C0040P00 for TR3271
Range: Not applicable
Objects: Lines
Profile Equivalent: PROGRAM
Default: None. This is a required attribute.
Range: CRT, ITI, PRT, PTP, or QUO for AM3270.
CRT or PTP for TR3271.
Objects: Subdevices
Profile Equivalent: None