A-2
CONFTEXT Paragraph Information
CONFTEXT Paragraph Information 
Table A-1 lists the CONFTEXT paragraphs that are relevant to AM3270/TR3271 
configuration and how the information in each paragraph is defined on G-series 
systems.
For more information about NonStop Kernel subsystem configuration, see the SCF 
Reference Manual for the Kernel Subsystem.
COUP-to-SCF Considerations
The COUP interface is no longer supported for G-series releases. COUP functionality 
is replaced by SCF. Although most COUP commands have a direct SCF equivalent, 
the method of configuration on G-series systems is very different from D-series 
systems. Refer to the SCF reference manuals listed in “About This Manual” for more 
information.
The following COUP commands have no SCF equivalent and cannot be used with G-
series systems: 
Table A-1. Defining CONFTEXT Paragraph Information on G-Series Systems
CONFTEXT Paragraph G-Series Definition
DEFINES Customizes a profile to be used later when configuring 
a DEVICE object type
CONTROLLERS Concentrator information is configured through the 
WAN subsystem
PATHS Not applicable for G-series systems
PERIPHERALS IOPs are configured through the WAN subsystem
ALLPROCESSORS Still exists in G-series CONFTEXT file