AM3270 Management Programming Manual
 COMMANDS AND RESPONSES
 DISCONNECT Command
 ZAM3-ERR-NOT-PTP-SU (5)
 Your management application tried to delete a link from or to
 a subdevice that is not a PTP subdevice. The subdevices that
 you disconnect must both be capable of using the pass-through
 protocol.
 ZAM3-ERR-TARGET-OBJNAME-INV (10)
 The object name for the target TR3271 subdevice does not
 comply with the valid format.
 ZSPI-TKN-ENDLIST indicates the end of a data list or an error
 list. This token is described in "SPI Standard Definitions"
 in Section 5 and the 
Distributed Systems Management (DSM)
Programming Manual
.
 Operational Notes
 • DISCONNECT is a sensitive command.
 • The line and subdevices must be in the STARTED summary state
 when this command is issued.
 • When the command is completed, the line and subdevices remain
 in the STARTED summary state.
 • To establish a link between an AM3270 and TR3271 subdevice,
 use the CONNECT command.
 6-46