AM3270 Management Programming Manual
 COMMANDS AND RESPONSES
 INFO Command
 PTP subdevice The defined screen size is as
 follows:
 Screen Size Record Size
 480 512
 960 1024
 1920 2048
 2560 3072
 3440 4095
 Printer The printer line length is used
 as the record size.
 ZREPOLL-INTVL A timestamp that specifies the time interval the
 AM3270 subsystem repolls the control unit when the
 control unit times out on poll. The default is
 value is 0. The valid range is 0 through 32767.
 ZTYPE A pair of integers that specifies the device type
 and subtype of the subdevice. The first integer
 is the device type, which depends on the protocol
 being used. The second integer is the subtype,
 which depends on the terminal being represented.
 The possible integer pairs are as follows:
 (5,0) The subdevice is a printer.
 (6,x) The subdevice is an ITI terminal.
 The value of x is an integer in the
 range 6 through 10 and is associated
 with the following screen sizes:
 ZTYPE Screen Size
 (6,6) 12 x 40
 (6,7) 24 x 80
 (6,8) 32 x 80
 (6,9) 43 x 80
 (6,10) 12 x 80
 6-60