AM3270 Management Programming Manual
COMMANDS AND RESPONSES
INFO Command
PTP subdevice The defined screen size is as
follows:
Screen Size Record Size
480 512
960 1024
1920 2048
2560 3072
3440 4095
Printer The printer line length is used
as the record size.
ZREPOLL-INTVL A timestamp that specifies the time interval the
AM3270 subsystem repolls the control unit when the
control unit times out on poll. The default is
value is 0. The valid range is 0 through 32767.
ZTYPE A pair of integers that specifies the device type
and subtype of the subdevice. The first integer
is the device type, which depends on the protocol
being used. The second integer is the subtype,
which depends on the terminal being represented.
The possible integer pairs are as follows:
(5,0) The subdevice is a printer.
(6,x) The subdevice is an ITI terminal.
The value of x is an integer in the
range 6 through 10 and is associated
with the following screen sizes:
ZTYPE Screen Size
(6,6) 12 x 40
(6,7) 24 x 80
(6,8) 32 x 80
(6,9) 43 x 80
(6,10) 12 x 80
6-60