AM3270 Management Programming Manual
 COMMANDS AND RESPONSES
 STATUS Command
 Bit 7 indicates a two-step READ is pending.
 Bit 8 indicates the subdevice is waiting for a real READ.
 Bit 9 is for internal use only.
 Bit 10 indicates the subsystem is attempting to connect the
 subdevice. This applies to PTP subdevices only.
 Bit 11 indicates the subsystem is attempting to disconnect
 the subdevice. This applies to PTP subdevices only.
 Bit 12 is not used.
 Bit 13 is not used.
 Bit 14 is for internal use only.
 Bit 15 is for internal use only.
 ZLAST-ERR is the last error detected on the queried subdevice.
 ZIS-PTP is a Boolean variable that specifies whether the
 subdevice is a pass-through protocol (PTP) subdevice. The
 value of this field can be one of the following:
 ZSPI-VAL-TRUE The subdevice is a PTP device.
 ZSPI-VAL-FALSE The subdevice is not a PTP device.
 ZHIS-SYS-NUM is the number of the system on which the AM3270
 subdevice resides. This field applies only to PTP subdevices.
 ZHIS-LDEV is the number of the line to which the AM3270
 subdevice is subordinate. This field applies only to PTP
 subdevices.
 ZHIS-SDN is the subdevice number of the AM3270 subdevice.
 This field applies only to PTP subdevices.
 ZHIS-CU is the controller number of the AM3270 subdevice.
 This field applies only to PTP subdevices.
 ZHIS-DA is the device address of the AM3270 subdevice. This
 field applies only to PTP subdevices.
 ZSPI-TKN-DATALIST indicates the beginning of a data list. This
 token is described in "SPI Standard Definitions" in Section
 5, "Common Definitions," and the 
Distributed Systems Management
programming Manual
.
 6-106