AM3270 Management Programming Manual
EVENT MANAGEMENT
74: ZAM3-EVT-INTL-ERR
Volatile Tokens
ZEMS-TKN-CU is a standard EMS token that contains the controller
and unit number. This token is present in the event buffer only
if the controller uses subchannel-type I/O addressing.
Event-Message Text
In the text message,
ldev
corresponds to the value of ZEMS-TKN-
LDEV,
n,n,%nn,%nnn
corresponds to the value of ZEMS-MAP-EXIOADDR,
ldevname
corresponds to the value of ZEMS-TKN-LDEVNAME, and the
remaining values are internal tokens.
Probable Cause
An internal error has been detected. After this event message is
issued, application requests are aborted and the AM3270 subsystem
recovers.
Recommended Action
If the AM3270 subsystem can recover from the internal error, you
can continue to run. Otherwise, report this and other related
event messages to your Tandem representative.
7-26