AM3270 Management Programming Manual
 EVENT MANAGEMENT
 74: ZAM3-EVT-INTL-ERR
 Volatile Tokens
 ZEMS-TKN-CU is a standard EMS token that contains the controller
 and unit number. This token is present in the event buffer only
 if the controller uses subchannel-type I/O addressing.
 Event-Message Text
 In the text message, 
ldev
 corresponds to the value of ZEMS-TKN-
 LDEV, 
n,n,%nn,%nnn
 corresponds to the value of ZEMS-MAP-EXIOADDR,
ldevname
 corresponds to the value of ZEMS-TKN-LDEVNAME, and the
 remaining values are internal tokens.
 Probable Cause
 An internal error has been detected. After this event message is
 issued, application requests are aborted and the AM3270 subsystem
 recovers.
 Recommended Action
 If the AM3270 subsystem can recover from the internal error, you
 can continue to run. Otherwise, report this and other related
 event messages to your Tandem representative.
 7-26