 EVENT MANAGEMENT
 158: ZAM3-EVT-CSS-UNEXP-BRKPT
 Volatile Tokens
 ZEMS-TKN-CU is a standard EMS token that contains the controller
 and unit number. This token is present in the event buffer only
 if the controller uses subchannel-type I/O addressing.
 Event-Message Text
 In the message text, 
ldev
 corresponds to the value of ZEMS-
 TKN-LDEV, 
n,n,%nn,%nnn
 corresponds to the value of ZEMS-MAP-
 EXIOADDR, 
ldevname
 corresponds to the value ZEMS-TKN-LDEVNAME,
path
 corresponds to the value of ZCOM-TKN-NEW-PATH, and 
param1
 corresponds to the value of ZAM3-TKN-CLIP-FUNC.
 Probable Cause
 The CLIP of the 6100 CSS encountered an unexpected breakpoint and
 has stopped.
 Recommended Action
 Note the value of 
param1
 in the message text and contact your
 Tandem representative.