COMMON DEFINITIONS
Data-Communications Standard Definitions
ZCOM-TKN-SEL-SUMSTATE specifies whether an object is selected
based on its current summary state. This modifier consists of
two fields, an enumerated field that indicates the summary state,
and a Boolean field that indicates whether objects currently in
that summary state are to be included in the information returned
by the subsystem. The STATUS command is the only AM3270 command
that supports the select-state modifier.
ZCOM-TKN-SUB indicates whether or not objects subordinate to the
object whose name appears in the object-name token are to be
affected by the command.
This token can appear in all AM3270 commands. If the object
type is ZCOM-OBJ-SU or ZCOM-OBJ-PROC, only the ZCOM-VAL-SUB-ALL
and the ZCOM-VAL-SUB-NONE values are accepted. These values,
however, have no effect on the command. The command is processed
as if the modifier were not present. If the value ZCOM-VAL-
SUB-ONLY is specified for the SU or PROC object, the command is
rejected.
If the object type is ZCOM-OBJ-LINE, the possible values of the
subordinate modifier vary with each command. In all commands
that accept ZCOM-OBJ-LINE as the object type, the value ZCOM-VAL-
SUB-NONE is accepted. This value has no effect on the command.
If the value ZCOM-VAL-SUB-ONLY is specified, only the objects
subordinate to the line are affected. The objects subordinate
to an AM3270 line are the subdevices on the line. If the
value ZCOM-VAL-SUB-ALL is specified, the objects subordinate to
the line as well as the LINE object itself are affected by the
command.
ZCOM-TKN-SWITCH-CPU specifies that the AM3270 process is to be
switched to another CPU. The value of this token indicates the
target CPU. If it is a single port environment, the path is also
changed.
ZCOM-TKN-SWITCH-PATH specifies that the path to the
Communications Interface Unit (CIU) is to be switched to the
backup path. The value of this token indicates the target path.
ZCOM-TKN-TARGET-OBJNAME specifies the name of the AM3270 subde-
vice to which you want to build or tear down a link. This token
is required when issuing the CONNECT or DISCONNECT command.
ZCOM-TKN-TARGET-OBJTYPE specifies the type of object to which you
want to build or tear down a link. This token is required when
you issue the CONNECT or DISCONNECT command and it must have the
value ZCOM-OBJ-SU.
5-15