AM3270 Management Programming Manual
 COMMANDS AND RESPONSES
 CONNECT Command
 ZCOM-ERR-CMD-INV-IN-SUMSTATE (-3)
 Your management application tried to connect a subdevice while
 the target TR3271 subdevice or the AM3270 subdevice was not
 in the STARTED summary state. Or, the line associated with
 one of the subdevices is in the DIAG (diagnosing) or STOPPED
 summary state.
 ZAM3-ERR-TARGET-OBJ-NOT-FOUND (3)
 Your management application tried to build a link to a TR3271
 subdevice that does not exist.
 ZAM3-ERR-NOT-PTP-SU (5)
 Your management application tried to build a link from or to
 a subdevice that is not a PTP subdevice. The subdevices that
 you connect must both be capable of using the pass-through
 protocol.
 ZAM3-ERR-TARGET-OBJNAME-INV (10)
 The object name for the target TR3271 subdevice does not
 comply with the valid format.
 ZSPI-TKN-ENDLIST indicates the end of a data list or an error
 list. This token is described in "SPI Standard Definitions"
 in Section 5 and the 
Distributed Systems Management (DSM)
Programming Manual
.
 Operational Notes
 • CONNECT is a sensitive command.
 • The line and subdevice must be in the STARTED summary state
 when this command is issued.
 • When the command is completed, the lines and subdevices remain
 in the STARTED summary state.
 • To disconnect the link between the AM3270 and TR3271
 subdevices, use the DISCONNECT command.
 6-36