ASAP 2.8 Messages Manual

HP NonStop ASAP Messages Manual429917-004
1-55
Conversational Interface (CI) and specify another volume, subvolume, or both. Once
you specify another location, restart the ASAP Monitor. An example of the ASAP CI
command is:
SET ASAPDSK on,PARAM "$vol.subvol"
1704
Cause. The Measure subsystem has a measurement data file with the same name as
ZASPxxx, where xxx is the ASAP ID. The disk SGP could not delete it.
Effect. ASAPDSK cannot obtain disk counters. Disk device status information is valid
when ASAPDSK cannot obtain the disk counters.
Recovery. Use the ASAP Conversational Interface (CI) to set ASAPDSK with a
different volume or subvolume than was previously specified. If you used the default,
try a volume other than $SYSTEM.
1705
err
is the Measure error returned from the Measure subsystem
Cause. The MEASFH process has trapped out.
Effect. ASAPDSK cannot obtain disk counters. Even though disk utilization samples
cannot be made, the disk device status information is still valid.
Recovery. Specify a different CPU for the MEASFH process by using the ASAP
Conversational Interface (CI) to specify CPU cpu-number in the SET DISK command;
then restart the ASAP Monitor.
1706
err
is the Measure error returned from the Measure subsystem
Cause. An incompatible MEASFH release was found on $SYSTEM.SYSxx.
Effect. ASAPDSK cannot obtain disk counters. Disk device status information is valid
when ASAPDSK cannot obtain the disk counters.
Set Disk param VOLUME/SUBVOL to another location
ASAPDSK MEASFH Trapped err
ASAPDSK Incompatible Measfh Release err