ASAP 3.0 Messages Manual
HP NonStop Messages Manual Page 233 of 407
dst
is the delta of the sample time for this PIN.
Cause. ASAP detected a 100-percent process control block (PCB) busy state,
possibly because of an internal interface failure with the operating system.
Effect. The PCB busy information is suspect.
Recovery. If the problem persists, contact your HP support representative and
provide all relevant information:
Descriptions of the problem and accompanying symptoms
Details from the messages generated
System number
Numbers and versions of all related products
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and a CPU dump, if applicable
Data Tokens.
ZEMS-TK7N-TEXT contains the message text.
ZASP-TKN-ASAP-ERRORNUM is ―1303‖.
1304: ZASP-EVT-DELTA-TOO-BIG
ProcessTime delta too big:last 2 INTs in .1 sec: pin#, dpt1,
dpt2
pin#
is the process identification number.
dpt1
is the third word of the process delta time for this PIN.
dpt2
is the last word of the process delta time for this PIN.
Cause. ASAP detected a 100-percent process control block (PCB) busy state,
possibly because of an internal interface failure with the operating system.
Effect. The PCB busy information is suspect.
Recovery. If the problem persists, contact your HP support representative and
provide all relevant information:
Descriptions of the problem and accompanying symptoms