ASAP 3.0 Server Manual
HP NonStop ASAP Server Manual    Page 214 of 342 
event 
INFO | CRITICAL [REPEAT] [NODISPLAY] [down] [-up] 
INFO 
configures ASAP to generate an informational event when the objective is 
not met. 
CRITICAL 
configures ASAP to generate a critical event when the objective is not met. 
REPEAT 
causes ASAP to repeat the event for each interval where the objective is 
not met. 
NODISPLAY 
overrides any global settings to suppress display of the event on the 
operator console. 
down 
is the event number to use for the down event, when the objective 
comparison fails. Events must be numbered in the range 6000 through 
9999. Event number 4000 is used when this is not specified. The ASAP 
EMS event template for the down event is not applied when custom down 
events are defined. 
-up 
is the event number to use for the up event, which is triggered when the 
objective comparison returns to normal after a failure. The number 
specified must be in the range 6000 through 9999. Event number 4001 is 
used when this is not specified. The minus sign must precede the up event 
number even if the down event number is not specified. The ASAP EMS 
event template for the up event is not applied when custom up events are 
defined. 
STATUS 
When events are turned on (using SET OBJECTIVESEVENT ON), status 
changes in ASAP system entities default to generate one critical EMS event. 
The STATUS attribute specifies changes to the default behavior for system 
entities. Use STATUS with ASAP user-defined entities to define all event 
behavior for status changes. 