ASAP 3.2 Messages Manual
HP NonStop Messages Manual Page 236 of 414
1301: ZASP-EVT-PROCESSINFO-ERROR
ProcessInfo Returns error: err, pin#
err
indicates the outcome of the PROCESSINFO call:
err
Meaning
0
Returns the status of the process CPU, PIN.
1
The process CPU, PIN does not exist or does not match the specified
criteria. The status for the next higher CPU, PIN in the specified
processor is returned. The four-word process ID for which status is being
returned reflects the process ID parameters, if present.
2
The process CPU, PIN does not exist, and no higher CPU, PIN exists in
the process that matches the specified criteria.
3
The process cannot communicate with the CPU.
4
The CPU is not present.
5
The system specified by sysnum could not be accessed.
99
A parameter error occurred.
pin#
is the process identification number.
Cause. The system could not get the program file name of the process. A process
went away between a GETPEEKPCBs call and a PROCESSINFO call.
Effect. The process information does not include a related program file name.
Recovery. Informational message only; no corrective action is needed.
Data Tokens.
ZEMS-TKN-TEXT contains the message text.
ZASP-TKN-ASAP-ERRORNUM is ―1301‖.
1302: ZASP-EVT-NO-DEVICE-NAME
Unable to get device name: err, pin#
err
indicates the outcome of a PROCESSINFO call, with either of these values:
0
indicates no error.
100
indicates that the device is not ready or that the controller is not operational.