Recovery. Specify a different CPU for the MEASFH process by using the ASAP
Conversational Interface (CI) to specify CPU cpu-number in the SET DISK command.
Then restart the ASAP Monitor.
Data Tokens.
ZEMS-TKN-TEXT contains the message text.
ZASP-TKN-ASAP-ERRORNUM is ―1707‖.
1708: ZASP-EVT-DSK-DATA-FILE-INUSE
ASAPDSK Measure Data File In Use err
err
is the Measure error returned from the Measure subsystem.
Cause. ASAPDSK could not create a Measure data file.
Effect. ASAPDSK cannot obtain disk counters.
Recovery. Stop and delete the measurement named ZASPxxx, where xxx is the
ASAP ID. Use the Measure interface MEASCOM.
Data Tokens.
ZEMS-TKN-TEXT contains the message text.
ZASP-TKN-ASAP-ERRORNUM is ―1708‖.
1709: ZASP-EVT-DSK-MAX-MEAS-REACHED
ASAPDSK Measure Data File In Use err
err
is the Measure error returned from the Measure subsystem.
Cause. ASAPDSK could not start a measurement. Maximum measurements have
been reached.
Effect. ASAPDSK cannot obtain disk counters.
Recovery. If possible, stop and delete unnecessary measurements. Restart the ASAP
Monitor once the Measure subsystem has fewer than 64 measurements configured.
Data Tokens.
ZEMS-TKN-TEXT contains the message text.
ZASP-TKN-ASAP-ERRORNUM is ―1709‖.