ASAP 3.2 Messages Manual
HP NonStop Messages Manual    Page 36 of 414 
1002 
Send to SGP pid error: err, type, read^L 
err 
is the file-system error number associated with the last operation on the file. 
type 
is the request type. 
read^L 
is the sum of the length of the SGP structure, in bytes. 
Cause. The Statistics Gathering process (SGP) is not receiving startup, shutdown, 
status, or other requests. This error could occur because of a version mismatch 
between the Monitor and Collect processes. For example, if a new Monitor is installed 
on one node in an ASAP network and the Collect process is not updated, the Collector 
does not recognize any new statistics types. 
Effect. Statistics are not being collected from the CPU. 
Recovery. The FILEINFO system call returned this error. For corrective action for the 
specified error code, see the Operator Messages Manual or the Guardian Procedure 
Errors and Messages Manual . 
Make sure all ASAP Collector and Server processes are at the same revision level. If 
the problem persists, contact your HP representative to file an HP Product Case. 
1003 
Send to COLLECT error: err 
err 
is the file-system error number associated with the last operation on the file. 
Cause. The Monitor did not send aggregate summary messages to the Collector. 
Effect. Data cannot be written to the Collect server. 
Recovery. The FILEINFO system call returned this error. For corrective action for the 
specified error code, see the Operator Messages Manual or the Guardian Procedure 
Errors and Messages Manual . 
Check if the Collector is installed. Make sure the Monitor and Collector are both up and 
running; you can do this by entering STAT C for the Collector and STAT for the 
Monitor. Check the network path connection. 
If the problem persists, contact your HP representative. 