ASAP 3.2 Messages Manual
HP NonStop Messages Manual Page 36 of 414
1002
Send to SGP pid error: err, type, read^L
err
is the file-system error number associated with the last operation on the file.
type
is the request type.
read^L
is the sum of the length of the SGP structure, in bytes.
Cause. The Statistics Gathering process (SGP) is not receiving startup, shutdown,
status, or other requests. This error could occur because of a version mismatch
between the Monitor and Collect processes. For example, if a new Monitor is installed
on one node in an ASAP network and the Collect process is not updated, the Collector
does not recognize any new statistics types.
Effect. Statistics are not being collected from the CPU.
Recovery. The FILEINFO system call returned this error. For corrective action for the
specified error code, see the Operator Messages Manual or the Guardian Procedure
Errors and Messages Manual .
Make sure all ASAP Collector and Server processes are at the same revision level. If
the problem persists, contact your HP representative to file an HP Product Case.
1003
Send to COLLECT error: err
err
is the file-system error number associated with the last operation on the file.
Cause. The Monitor did not send aggregate summary messages to the Collector.
Effect. Data cannot be written to the Collect server.
Recovery. The FILEINFO system call returned this error. For corrective action for the
specified error code, see the Operator Messages Manual or the Guardian Procedure
Errors and Messages Manual .
Check if the Collector is installed. Make sure the Monitor and Collector are both up and
running; you can do this by entering STAT C for the Collector and STAT for the
Monitor. Check the network path connection.
If the problem persists, contact your HP representative.