ASAP 3.2 Messages Manual
HP NonStop Messages Manual Page 39 of 414
1009
Sync, Clock Corrected: delta
delta
is the time difference, in seconds.
Cause. The synchronization clock is now set correctly.
Effect. The synchronization clock is now operating correctly.
Recovery. This message is informational only. No corrective action is required.
1010
Sync, Can’t Set Clock: delta
delta
is the time difference, in seconds.
Cause. The system cannot reset the synchronization clock correctly.
Effect. Synchronization with the Server is not being accomplished.
Recovery. Be sure you have the right security to perform the SYNC operation; you
must be in the super user group. Retry the request later. If the problem persists,
contact your HP representative.
1011
Short request received count, buf, pid
count
is the length of the message, in bytes.
buf
is the first word of the received request message.
pid
is the requester’s process ID.
Cause. The message received was not recognized because of its short length.
Effect. The message could not be processed.
Recovery. If the problem persists, contact your HP representative.