ASAP 3.2 Messages Manual
HP NonStop Messages Manual    Page 53 of 414 
paths 
is the index to the internal network configuration table. 
Cause. The Expand SGP could not find the path for this network line-handler device 
in the network line-handler configuration file. 
Effect. No statistics were returned for the network line handler. 
Recovery. Check that the Expand Manager to is present, up, and running. If the 
problem persists, contact your HP representative. 
1210 
NewProcess $System.System.Ozexp Error <0:7>,<8:15>: 
err 
is a number indicating the outcome of the process creation attempt, where err 0:7 
is: 
0 
No error, process created 
1 
 Warning that the process had undefined externals but was 
started 
2  
No process control block available 
3  
 File-system error occurred on program file; error 8:15 = file-
system error number 
4  
Unable to allocate map 
5 
File error on swap file; error 8:15 = file-system error 
number 
6  
Invalid file format; 
error 8:15 
= error subcode, and 
  error 15 
  = 0, program file is in 
error 
= 1, library file is in 
error 
7  
Unlicensed privileged program 
8  
Process name error; error 8:15 = file-system error number 
9  
Library conflict 
10 
  Unable to communicate with system Monitor process; error 
8:15 = file-system error number 
11  
  File-system error occurred on library file; error 8:15 = file-
system error number 
12  
Program file and library file specified are same file 
13  
  Extended data segment initialization error; error 8:15 = file-
system error number 