ASAP 3.2 Messages Manual

HP NonStop Messages Manual Page 67 of 414
pin#
is the PIN number of the process:
0
Indicates no error
100
Indicates the device is not ready or the controller is not operational
Cause. The system could not obtain the device name of the process. The process
probably went away before the device name was obtained.
Effect. The process information does not include a related device name.
Recovery. This message is informational only. No corrective action is required.
1303
pin:ProcessTime delta:Sampletime delta in .1 sec: pin#, dpt,
dst
pin#
is the PIN of the process.
dpt
is the delta of the process time for this PIN.
dst
is the delta of the sample time for this PIN.
Cause. ASAP detected a 100 percent PCB busy, possibly because of a NonStop
operating system internal interface failure.
Effect. The PCB busy information is suspect.
Recovery. If the problem persists, contact your HP representative.
1304
ProcessTime delta too big:last 2 INTs in .1 sec: pin#, dpt1,
dpt2
pin#
is the PIN of the process.
dpt1
is the third word of the delta time for this PIN.