ASAP 3.2 Messages Manual
HP NonStop Messages Manual    Page 77 of 414 
Recovery. Stop and delete the measurement named ZASPxxx, where xxx is the 
ASAP ID. Use the Measure interface MEASCOM. 
1709 
ASAPDSK 64 Measurements Configured err 
err 
is the Measure error returned from the Measure subsystem 
Cause. ASAPDSK could not start a measurement. Maximum measurements were 
reached. 
Effect. ASAPDSK cannot obtain disk counters. Disk device status information is valid 
when ASAPDSK cannot obtain the disk counters. 
Recovery. If possible, stop and delete unnecessary measurements. Restart the ASAP 
Monitor once the Measure subsystem has fewer than 64 measurements configured. 
1710 
ASAPDSK Measctl Pool Space Error err 
err 
is the Measure error returned from the Measure subsystem 
Cause. ASAPDSK could not start a measurement. The pool space is full for code 
range addresses in the MEASCTL process. 
Effect. ASAPDSK cannot obtain disk counters. Disk device status information is valid 
when ASAPDSK cannot obtain the disk counters. 
Recovery. If possible, stop and delete unnecessary measurements. Restart the ASAP 
Monitor once the Measure subsystem has fewer than 64 measurements configured. 
1711 
ASAPDSK Measure CPU Memory error err 
err 
is the Measure error returned from the Measure subsystem 
Cause. ASAPDSK could not start a measurement in the specified CPU or in the 
default CPU (CPU 0). 
Effect. ASAPDSK cannot obtain disk counters. Disk device status information is valid 
when ASAPDSK cannot obtain the disk counters. 