ASAP 3.2 Server Manual
HP NonStop ASAP Server Manual    Page 286 of 381 
CPU cpu-num 
defines the CPU that the SWAP SGP process will reside in.  
ON|OFF 
enables or disables network-wide swap availability reporting. 
OBJECT ASAP-swap-program-filename 
specifies the name of the Swap SGP program file. The default is 
$SYSTEM.SYSTEM.ASAPSWP. 
PARAMETERS 
specifies swap-specific parameter string to pass to each Swap SGP at startup. 
RATE #mins 
overwrites the ASAP default rate parameter for the Swap SGP only. 
Instructs the Swap SGP to sample at this rate. 
Examples 
+SET SWAP ON, CPU 3, OBJECT $SYSTEM.SYSTEM.ASAPSWP,PARAMETERS 
“RATE 5” 
SYNC minutes, frequency 
specifies the interval (in minutes past midnight) and the number of times 
(frequency) that the system clock of the node in which the Monitor resides is 
automatically synchronized to the system clock of the node specified with the 
Collect option. 
If Monitor and Collect are in the same node, this option has no meaning. For this 
SYNC option to function, the Monitor must be accessed by someone with a super-
group user ID. For more information, see SYNCSLOW ON | OFF.  
minutes  
specifies the number of minutes past midnight. 
The default number of minutes is 0. 
frequency 
specifies the number of times the Monitor’s system clock is automatically 
synchronized to the node’s system clock. The default frequency is 0.  
The default is 0,0. 