ASAP 3.2 Server Manual

HP NonStop ASAP Server Manual Page 286 of 381
CPU cpu-num
defines the CPU that the SWAP SGP process will reside in.
ON|OFF
enables or disables network-wide swap availability reporting.
OBJECT ASAP-swap-program-filename
specifies the name of the Swap SGP program file. The default is
$SYSTEM.SYSTEM.ASAPSWP.
PARAMETERS
specifies swap-specific parameter string to pass to each Swap SGP at startup.
RATE #mins
overwrites the ASAP default rate parameter for the Swap SGP only.
Instructs the Swap SGP to sample at this rate.
Examples
+SET SWAP ON, CPU 3, OBJECT $SYSTEM.SYSTEM.ASAPSWP,PARAMETERS
“RATE 5”
SYNC minutes, frequency
specifies the interval (in minutes past midnight) and the number of times
(frequency) that the system clock of the node in which the Monitor resides is
automatically synchronized to the system clock of the node specified with the
Collect option.
If Monitor and Collect are in the same node, this option has no meaning. For this
SYNC option to function, the Monitor must be accessed by someone with a super-
group user ID. For more information, see SYNCSLOW ON | OFF.
minutes
specifies the number of minutes past midnight.
The default number of minutes is 0.
frequency
specifies the number of times the Monitor’s system clock is automatically
synchronized to the node’s system clock. The default frequency is 0.
The default is 0,0.