ASAP 3.2 Server Manual

HP NonStop ASAP Server Manual Page 311 of 381
SYNC Command
The SYNC command requests the Monitor on the specified node to set the NonStop
OS time of day clock to the NonStop OS time of day clock on the node where the
Collect server resides.
SYNC [ \* ] [ MONITOR ]
[ \node-name] [ [.] ppd-name ]
\*
synchronizes information on all nodes.
MONITOR
synchronizes information on the Monitor process.
node-name
specifies the individual system for which information is to be displayed.
ppd-name
specifies a process pair directory name. The process pair directory is a list of the
process names and corresponding pairs of process numbers that make up each
process kept by the NonStop OS operating system.
Example
This example shows how to synchronize the Chicago Monitor’s Greenwich Mean Time
(GMT) to the San Francisco Collector’s GMT:
+ SET COLLECT \SANFRAN
+ STARTUP \SANFRAN COLLECT ! San Francisco collector startup
+ STARTUP \CHICAGO MONITOR ! Chicago Monitor startup
+ SYNC \CHICAGO ! Sync CHICAGO gmt to SANFRAN gmt
SYSTEM Command
The SYSTEM command specifies another default node name or number. Entering
SYSTEM alone sets the system to the local system name.
SYSTEM [ \node-name ]
[ \node-number ]