Asynchronous Terminals and Printer Processes Configuration and Management Manual

Table Of Contents
Managing ATP6100 Using the
Subsystem Control Facility (SCF)
Asynchronous Terminals and Printer Processes Configuration and Management Manual424280-003
6-19
LOAD LINE Command
LOAD LINE Command
The LOAD LINE command downloads the Data Link Control (DLC) task to the
SWAN/SWAN 2 concentrator. LOAD LINE is a sensitive command.
Command Syntax for the LOAD LINE Command
The LOAD LINE command has the following syntax:
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
LINE line-name
designates the line to be downloaded. If you omit line-name, the assumed line
is aborted (see the SCF Reference Manual for G-Series RVUs or SCF Reference
Manual for H-Series RVUs for details about the ASSUME command).
Considerations for the LOAD LINE Command
The SUB and SEL options are not supported.
The LOAD LINE command is valid only if the line is in the STOPPED state.
Line loaded means the clip code is downloaded.
Examples of the LOAD LINE Command
The following SCF command loads line $ATPS1.
->LOAD LINE $ATPS1
LOAD [ /OUT file-spec / ] LINE line-name