Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
 
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

ATP6100 Subsystem Error Messages
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
A-3
About ATP6100 Errors
ATP6100 Error 00512 
Cause. The START command was rejected due to an inconsistent baud rate and 
interface to the SU, or inconsistent SU baud rate and LINE controller type, or 
inconsistent SU interface and LINE controller type.
Effect. The START command is not executed.
Recovery. Alter the baud rate and interface to the consistent values, and execute the 
START command again.
ATP6100 Error 00513 
Cause. The START SU command was rejected because the LINE is not in the 
STARTED state.
Effect. The specified SU is not started.
Recovery. Start the line and then START the SU.
ATP6100 Error 00514 
Cause. The ALTER SU command was rejected because the given modifier is not valid 
for the current TYPE and SUBTYPE of the line.
Effect. The ALTER SU command is not performed.
Recovery. Use the valid modifier for the current TYPE and SUBTYPE of the line.
ATP6100 Error 00515 
Cause. The TRACE BACKUP command was rejected because the current process is 
not the primary or the backup process does not exist or is unable to communicate with 
the backup process.
Effect. The TRACE BACKUP command is not executed.
Recovery. Verify that if the backup CPU is up. If it is not up, reload the CPU.
ATP6100 00512 START command rejected because of invalid 
combination of baudrate, interface, and controller type.
ATP6100 00513 name not started because line is not in started 
state.
ATP6100 00514 Alter SU rejected because given attribute is 
not valid for the current TYPE of the line.
ATP6100 00515 Backup Process does not exist or unable to 
communicate with the Backup Process.