Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

ATP6100 Subsystem Error Messages
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
A-4
About ATP6100 Errors
ATP6100 Error 00517
Cause. The START command was rejected because of a CSM download error. The
error could be caused by an improper download file.
Effect. The START command is not executed.
Recovery. Verify that the download file is correct.
ATP6100 Error 00518
Cause. The ABORT or STOP SU command was rejected due to a CLIP error.
Effect. The ABORT or START command is not executed.
Recovery. Check the status and statistics of the line for any errors.
ATP6100 Error 00519
Cause. The ALTER SU command failed because the ETXFLOW modifier is valid only
for subtype 32 subdevices.
Effect. The ALTER SU command is not executed.
Recovery. Alter the ETXFLOW modifier only if the subdevice is of subtype 32.
ATP6100 Error 00520
Cause. The ALTER SU command failed because the VFU72LINE modifier is valid
only for subtype 4 devices.
Effect. The ALTER SU command is not executed.
Recovery. Alter the VFU72LINE modifier only if the device is of subtype 4.
ATP6100 00517 START command failed due to CSM download error.
ATP6100 00518 STOP failed due to CLIP error.
ATP6100 00519 Invalid attribute and subtype combination.
ETXFLOW is valid only for subtype 32 subdevices.
ATP6100 00520 Invalid attribute and subtype combination.
VFU72LINE is valid only for subtype 4 devices.