Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
 
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

Printer Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
4-11
Printer Modifiers
Printer Modifiers
This subsection describes all modifiers contained in the printer profiles and all other 
modifiers that can be used with the ATP6100 printer profiles. For detailed information 
on using the Subsystem Control Facility (SCF) to alter the default values for the 
duration of the current session, refer to Section 6, Managing ATP6100 Using the 
Subsystem Control Facility (SCF). For detailed information on permanently altering the 
modifier default values contained in the printer profiles or creating a new profile, refer 
to the WAN Subsystem Configuration and Management Manual.
ASYNC 
This modifier specifies the operational class of the download module as asynchronous. 
If an appropriate module is not found in the download file, the operation terminates. 
When the ASYNC modifier is included in the PROFILE file, the ConMgr process 
checks to make sure that the operational modifier specified in the microcode file 
matches the line configuration. If they do not match, the microcode download does not 
occur; however, you will not receive an SCF error. If the operational modifier does not 
match the line configuration, you will receive a system error stating that the microcode 
was not downloaded after the attempted download to the CLIP.
AUTOANSWER
This modifier enables automatic modem answering. In AUTOANSWER mode, Data 
Terminal Ready (DTR) and Request To Send (RTS) signals are raised by the I/O 
software to allow incoming calls from the printer to be answered. Once the phone has 
been answered, an application can write to the printer without any special modem 
control calls. This allows any program that can access the printer locally to access it 
remotely as well. In AUTOANSWER mode, the communications line is not 
disconnected when the file is closed.
AUTOLOAD
This modifier specifies that the CONMGR automatically downloads the line interface 
unit (LIU) if the LIU responds to a status probe with an error condition.
Application: Serial printers
Application: Serial printers
See also: NOAUTOANSWER
Application: SWAN/SWAN 2 concentrator
See also NOAUTOLOAD