Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index
Printer Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
4-22
Printer Modifiers
RECSIZE n
This modifier specifies the record size, in bytes, for the printer. The record size is the
maximum number of characters transferred in a line, after which the line is terminated
(for example, with a CR and an LF). Newer graphics and dot-matrix printers may
require a value greater than the default.
REVTPAUSE
This modifier enables the reverse transmit pause flow-control handshake.
REVTPAUSE provides the same function as TPAUSE, except that it is triggered by the
opposite polarity of pin 12. REVTPAUSE requires RS232/EIA.
The following illustrates the difference between REVTPAUSE and TPAUSE.
RS232
This modifier specifies the concentrator interface as RS-232C.
RS449
This modifier specifies the concentrator interface as RS-449.
Application: SWAN/SWAN 2 concentrator
Units: Characters (bytes)
See also: DEVRSIZE (when configuring subdevices)
Application: Serial printers
See also: NOREVTPAUSE
SRLD Signal (pin 12) TPAUSE REVTPAUSE
Set (HIGH) Pause Transmit
Reset (LOW) Transmit Pause
Application: Serial printers
See also: EIA
Application: 5577 serial printers only