Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

Terminal Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
5-12
Terminal Modifiers
Terminal Modifiers
This subsection describes all modifiers contained in the terminal profiles and all other
modifiers that can be used with the ATP6100 terminal profiles. For detailed information
on using the Subsystem Control Facility (SCF) to alter the default values for the
duration of the current session, refer to Section 6, Managing ATP6100 Using the
Subsystem Control Facility (SCF). For detailed information on permanently altering the
modifier default values contained in the terminal profiles or creating a new profile, refer
to the WAN Subsystem Configuration and Management Manual.
ASYNC
This modifier specifies the operational class of the download module as asynchronous.
If an appropriate module is not found in the download file, the operation terminates.
When the ASYNC modifier is included in the PROFILE file, the ConMgr process
checks to make sure that the operational modifier specified in the microcode file
matches the line configuration. If they do not match, the microcode download does not
occur; however, you will not receive an SCF error. If the operational modifier does not
match the line configuration, you will receive a system error stating that the microcode
was not downloaded after the attempted download to the CLIP.
AUTODCONNECT
This modifier supports European CCITT-standard, full-duplex modems. It causes the
system to monitor the Carrier Detect (CD) signal in addition to its normal monitoring of
the Data Set Ready (DSR) signal during read and write operations.
If an error occurs during processing of a CONTROL 11 (modem connect operation),
the communications line is disconnected.
AUTOLOAD
This modifier specifies that the CONMGR automatically downloads the line interface
unit (LIU) if the LIU responds to a status probe with an error condition.
Application: All terminals
Application: All terminals
Application: SWAN/SWAN 2 concentrator
See also NOAUTOLOAD