Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index
Terminal Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
5-15
Terminal Modifiers
For 6530 terminals, if CHAR8 and NONE are specified, NOCHECK must also be
specified.
CHECK
This modifier directs the system to perform parity checking on data sent from the
terminal according to the specified parity modifier (EVEN or ODD).
CLBFRAMESIZE n
This modifier changes the default frame size. If you specify a value larger than the
range, the IOP changes the value to the maximum allowed.
CLBRETRIES n
This modifier specifies the number of retries for requests. The default value allows
optimum resource use. A value larger than the default may result in excessive retries.
CLBTIMEOUT n
This modifier specifies the CLB timeout. The default of 800 (8 seconds) allows optimal
resource use. A value larger than the default may result in excessive timeouts.
Application: All terminals
See also: EVEN, NOCHECK, NONE, ODD
Application: SWAN/SWAN 2 concentrator
Default: n = 300
Units: Words
Range: 150 through 600
Application: SWAN/SWAN 2 concentrator
Default: n = 4
Range: 0 through 63
Application: SWAN/SWAN 2 concentrator
Default: n = 800 (8 sec)
Units: .01 seconds
Range: 350 through 32767