Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

Terminal Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
5-22
Terminal Modifiers
HARD
This modifier specifies that the concentrator is directly connected to the terminal
through a set of wires (a cable).
HDTURN1 n / HDTURN2 n
These modifiers specify turnaround characters for certain half-duplex modems and for
terminals that require one or two special turnaround characters to switch between the
receive and send modes.
HIGHPIN OFF
This modifier specifies that the IOP for the serial printer be configured at a low PIN so
that the serial printer can be accessed by C-series systems.
INTCHAR
This modifier specifies that the concentrator is to issue an interrupt to the I/O
subsystem whenever it receives an interrupt character from the terminal.
For conversational mode, the interrupt characters are backspace (BS), line cancel
(CAN), end-of-file (EOF), and carriage return (CR).
For page mode, the interrupt character is the page-termination character.
Application: All terminals
See also: MODEM
Application: All terminals
Units: ASCII characters
Range: All characters in ASCII character set
Default: n = 0
Application: Currently unsupported
Note. The HIGHPIN OFF modifier has no effect on the ATP6100 line-handler process running
on G-series or H-series RVUs.
Application: All terminals
See also: NOINTCHAR