Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index
Terminal Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
5-24
Terminal Modifiers
LINEERRDISABLE
This modifier specifies that console message 165, with a communications line interface
processor (CLIP) status of 8, is not sent to the system console.
LINETERM n
This modifier specifies the line-termination character, in this case a carriage return
(CR).
LOCALPOOLPAGES n
This modifier specifies the number of pages used for calculating local pool space. The
default value is calculated to optimize most systems. Larger values increase the
amount of host memory allocated.
MAXLOCALAREA n
This modifier specifies the maximum buffer size that an application process can
request.
MODEM
This modifier specifies that the concentrator is connected to the terminal through a pair
of modems.
For a modem connection, you must specify MODEM and EIA and either BAUD n or
DUAL212.
Application: SWAN/SWAN 2 concentrator
Application: All terminals
Default: n = 13 (carriage return)
Application: SWAN/SWAN 2 concentrator
Default: n = 60
Units: 1024-word pages
Range: 1 through 63
Application: SWAN/SWAN 2 concentrator
Default: n = 2048
Range: 1024 through 32767
Units: Words
Application: All terminals
See also: HARD