Asynchronous Terminals and Printer Processes Configuration and Management Manual
Table Of Contents
- What’s New in This Manual
- About This Manual
- 1 Configuration Quick Start
- 2 Overview of the ATP6100 Subsystem
- 3 Configuring the ATP6100 Subsystem
- 4 Printer Profiles and Default Modifiers
- 5 Terminal Profiles and Default Modifiers
- 6 ManagingATP6100Usingthe SubsystemControlFacility(SCF)
- 7 PTrace Facility for ATP6100
- A ATP6100 Subsystem Error Messages
- B SCF Command Summary for ATP6100
- ABORT LINE Command
- ABORT SU Command
- ACTIVATE SU Command
- ALTER LINE Command
- ALTER SU Command
- INFO LINE Command
- INFO SU Command
- LOAD LINE Command
- START LINE Command
- START SU Command
- STATS LINE Command
- STATS SU Command
- STATUS LINE Command
- STATUS SU Command
- STOP LINE Command
- STOP SU Command
- SUSPEND SU Command
- SWITCH PROC Command
- TRACE LINE Command
- VERSION PROC Command
- C Moving to G-Series or H-Series RVUs
- Glossary
- Index

Terminal Profiles and Default Modifiers
Asynchronous Terminals and Printer Processes Configuration and Management Manual—424280-003
5-29
Terminal Modifiers
PROFILEID
This modifier keyword specifies the profile version. This is used to avoid
IOPOBJECT and Profile Version mismatch.
PROGRAM file_name
This modifier specifies the name of the line interface unit (LIU) download module for a
terminal.
RC
For terminals, this modifier specifies that a half-duplex, Bell 202-type modem with
reverse channel is connected to an LIU-1. These modems require that Request To
Send (RTS) be dropped when switching from transmit to receive.
RC checks the XFERSIZE value before it transmits data.
RECSIZE n
This modifier specifies the record size, in bytes, for the terminal. The record size is the
maximum number of characters transferred in a line, after which the line is terminated
(for example, with a CR and an LF). Newer graphics and dot-matrix printers may
require a value greater than the default.
Application: All terminals and printers
Default: Depends on IBM
Range: Default value cannot be altered
Application: SWAN concentrator
Default: file_name = C1094P00
OR
Application: SWAN 2 concentrator
Default: file_name = C1094Q00
Note. By default, profiles contain the value C1094P00 (for SWAN). To add an ATP line on a
SWAN 2 concentrator C1094Q00 has to be specified explicitly.
Application: All terminals
See also: NORC, TPAUSE, REVTPAUSE
Application: SWAN/SWAN 2 concentrator
Units: Characters (bytes)
See also: DEVRSIZE (when configuring subdevices)