Asynchronous Terminals and Printer Processes Programming Manual
 CONSOLE MESSAGES
 Console Error Messages Sent by SERIALPRINTPROCESS
 The parameter values are interpreted as follows:
 For controller errors (
parameter-1
=%000213), 
dev-status
 contains interrupt status from the controller and both
parameter-2
 and 
parameter-3
 are %000000.
 For the model 5520 printer:
dev-status
 is the primary status returned from the
 printer.
parameter-1
 is the auxiliary status word if bits
 9 through 11 of 
dev-status
 are equal to 7; otherwise,
parameter-1
 is %000000.
parameter-2
 is the GUARDIAN file-system error number.
parameter-3
 is %000000.
 SYSTEM The system waits until the problem is
 ACTION: corrected.
 RECOVERY: Check the printer for a possible problem.
 For the model 5530 printer:
dev-status
 is the primary status returned from the
 printer.
parameter-1
 is the auxiliary status if the primary
 status indicates that one is available.
parameter-2
 is the GUARDIAN file-system error number.
parameter-3
 is %000000.
 Operator console message #4 is issued for the following
 file-system errors:
 Decimal Octal Description
 120 %000170 Data Parity Error
 121 %000171 Data Overrun Error
 139 %000213 Controller Error
 140 %000214 Modem Error |
 190 %000276 Device Error
 191 %000277 Device Power-On
 SYSTEM The system waits until the problem is
 ACTION: corrected.
 RECOVERY: Check the printer for a possible problem.
 November 1987 A-7