Asynchronous Terminals and Printer Processes Programming Manual
 CONTROL, SETMODE, AND SETPARAM FOR TERMINALS
 SETMODE Operations
 67 = AUTODCONNECT for full-duplex modems. Monitor carrier
 detect or data set ready.
parameter-1
 = 0 disable AUTODCONNECT (default)
 1 enable AUTODCONNECT
parameter-2
 is not used.
 110 = Set shift in/shift out (SISO) code extension.
parameter-1
 = 0 disable SISO (default)
 1 enable SISO
 NOTE
 SETMODE 110 is supported in ITI protocol when used for
 6530 terminals.
parameter-2
 is not used.
 113 = set screen size.
parameter-1
 = screen width (40, 66, 80, or 132)
parameter-2
 = screen length (25 or 28)
last-parameters
 is an integer reference that contains two
 elements.
last-parameters
[0] = old 
parameter-1
 [1] = old 
parameter-2
 NOTE
 | SETMODE 113 is supported by both ATP6100 and TERMPROCESS.
 114 = download 6530 emulation code.
parameter
 = 0 stop downloading (default)
 1 start downloading
 B-6 November 1987