Asynchronous Terminals and Printer Processes Programming Manual
 CONTROL, CONTROLBUF, AND SETMODE FOR PRINTERS
 SETMODE Operations
 NOTE
 The 5520 printer (subtype 4) supports the following baud
 rates: 110, 150, 300, 600, 1200, 2400, 4800, and 9600.
 The 5530 (subtype 6) supports the following baud rates:
 75, 150, 300, 600, 1200, 2400, 4800, and 9600.
 The default is what was specified at SYSGEN. If none
 is specified, 9600 is used.
parameter-2
 is not used.
 23 = set character size.
parameter-1
 = 2 7 bits
 3 8 bits
parameter-2
 is not used.
 24 = set parity generation by system.
parameter-1
 = 0 odd
 1 even
 2 none
parameter-2
 is not used.
 25 = set form length. For subtype 3:
parameter-1
 = length of form in lines
parameter-2
 is not used
 26 = set or clear vertical tabs. For subtype 3:
parameter-1
 = 0 (line-number - 1) where tab is to be set
 1 clear all tabs except line 1
 NOTE
 There is always a vertical tab stop at line 1 (top
 of form).
parameter-2
 is not used
 C-4 November 1987