Asynchronous Terminals and Printer Processes Programming Manual
 3681 MULTIFUNCTION CONTROLLER
 System Generation for the 3681
 FLOW CONTROL SUPPORTED BY THE 3681 |
 |
 |
 The 3681 supports the following flow-control mechanisms for |
 subtype 2 and 4 terminals and serial printers (DTR-type printers) |
 that are not manufactured by Tandem. |
 |
 • XON/XOFF flow control |
 |
 • ETX(ENQ)/ACK flow control |
 |
 • CTS-DTR flow control in conjuction with TPAUSE and REVTPAUSE |
 |
 • Tandem Asynchronous Protocol (TAP) |
 |
 • Transparent Tandem Asynchronous Protocol (T-TAP) |
 |
 |
 |
 |
 SYSTEM GENERATION FOR THE 3681 |
 |
 |
 The system generation process for the 3681 Multifunction |
 Controller (MFC) is the same as for ATP6100 with CSSASYNC and |
 CSSPRINT. However, the 3681 MFC SYSGEN modifier requirements are |
 different in the following respects: |
 |
 • The 3681 requires the ASYNCPROC macro instead of the |
 ASYNCTERMPROC macro. |
 |
 • The 3681 does not require a CSM process. |
 |
 • The 3681 does not require a PATHS paragraph. |
 |
 • The 3681 requires a MULTIFUNCTION CONTROLLERS paragraph. |
 |
 • The 3681 requires the MICROCODE FILES paragraph defined as |
 M3681. |
 |
 • The 3681 does not support the CLBFRAMESIZE, STARTBOOT, |
 STARTDOWN, AUTOLOAD, and PROGRAM modifiers. These modifiers |
 are not rejected at system generation time; they are merely |
 blanked out. |
 |
 • The 3681 does not support the 6511 and 6512 entries in the |
 PERIPHERALS paragraph. |
 |
 November 1987 F-3